heat preservation nail is insulation board fixed on the wall of a kind of special engineering plastic bolts. Of exterior wall thermal insulation for heat preservation nail is the anchor pieces, widely used in building decoration, wall BaoWenWu anchorage. By galvanized screws, nylon tube rises and the fixed wafers. Depending on the insulation layer thickness, cent is a variety of specifications.

components:

bar consists of three parts: one is made of nylon sleeve; Second, the casing of galvanized steel screws; Three is the nylon disc before casing ( To gland insulation board) 。 Its length varies according to the thickness of insulation board.

application:

it is widely used in building decoration, wall BaoWenWu anchorage. It has anti-aging, temperature shock resistance, anti-corrosion, cold heat; High bearing capacity, high pressure, good tensile performance; After loading is not easy to deformation, moisture, vibration, and good thermal insulation, etc. The installation of the installation is simple, do not need special tools. Galvanized screw well solve the corrosion problems, good durability, and low heat transfer performance of nylon material, the winter is not cold bridge, high efficiency and energy saving. According to the wall material and anchorage exterior wall materials by different roughly divided into solid wall insulation nails, hollow brick is special heat preservation nail, wire mesh is special heat preservation nail and equipped mould.

main specifications:

8 x 62 x 72 x 82 x 192, 8 * 102 * 112. 8×122,8×132,8×152,8×182, 8×202,8×212

  8×60,8×80,8×100。 8×120,8×140, 8×150,8×160。

10×62×72, 10×82×192, 10×102, 10×112。 10×122,10×132,10×152,10×182, 10×202,10×212

  10×60,10×80,10×100。 10×120,10×140, 10×150,10×160。

performance parameters:

according to JG149 - 2003 exterior insulation standards;

a single heat preservation nail by residual 0 or higher. 3 kn

anchor pipe diameter 0. 7 - 0. 8

coefficient of thermal conductivity '0. 06

anchoring nails outside dish; 50 mm

- use temperature 40°- - - - - - - 70 °

product categories:

fission insulation nails and conjoined bar

insulation nailed the insulation on the market is one of the basic, easy to use.

158 - at the same time the new standards 2004 also is to implement new standard;

a single nail insulation bearing capacity; '0. 8 kn

coefficient of thermal conductivity '0. 004

anchoring nails outside dish of 56 mm

the arrangement of exterior wall thermal insulation nails. Extruded board exterior insulation system anchor pieces installation number; 1-10 layer on average 6 / ㎡, 11 - 20 an average of seven/square meter 21-26 layer 9 / ㎡. Any area is greater than zero. 1 ㎡ monolithic pull must add the anchoring piece, the number depending on the shape and site condition; In Yang Angle, under the eaves, around the edge of the hole, should increase the anchoring piece, the density of the distance is not more than 300 ㎜, is apart from the edge at the grass-roots level is not less than 60 mm