Sub-station

MPS

Staple of floor heating construction matters needing attention

by:MPS     2020-10-14

the card nail has the construction speed is quick, the proportion of small, light weight, easy handling and transportation of all kinds of characteristics. Staple of floor heating material has the advantages of recycling production is big, the cost is low, the installation of high efficiency, can save a lot of construction costs and shorten the installation date.

floor heating staple summary:

construction, construction personnel to nail card U side by hand gently knead, make the staple of u-shaped opening distance is basically consistent with that of pipe diameter, and inserted along the wall in the foam cement or benzene board, relying on the wire itself outward tension wire and foam cement layer or benzene board to increase the friction, so as to prevent nail wire card from foamed cement layer or benzene board pop up in a purpose.

now mainly used in the construction of floor heating from 16 or 20 floor heating tube, so the floor heating with card also basically with 16 or phi phi 20 ( The circular arc of the staple diameter) Give priority to. Because the foam cement layer or the thickness of benzene plate, generally at about 20 mm, coupled with the diameter of the floor heating pipe, so the open distance general design for the 3 card pin. 5 - 4. 0 cm, the card nailed on the total length control in 100 - 125mm。 Card nail openings through long, nail arc is stuck on the top can't closely contact with floor heating pipe, so that the card can't nail fixed pipe. Long staple openings through short, easy to cause nail with a foam cement layer or benzene board contact depth is not enough, the friction is reduced, so that the floor heating pipe fixed insufficient. So in floor heating construction according to their own actual situation to choose suitable openings nail length of card, in order to achieve the ideal effect of construction.

staple use installation, simple, do not need professional technical operations staff construction. Geothermal card nail fixed after installation does not affect the geothermal heating coefficient, pipes with plastic material, surface hardness and thermal expansion coefficient, don't touch bad wound tubes.

this website: https://www. 国会议员, insulationpins。 com/news/499。 HTML keywords: staple of floor heating construction, staple of floor heating, geothermal card pin
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...